binder M12-A WINKELDOSE F. 6-8MM KÄFIGZUGFEDER

product number: 99 0524 52 04

  • Manufacturer: binder
Picture may vary

Description:
M12 Female angled connector, Contacts: 4, 6.0-8.0 mm, unshielded, wire clamp, IP67
From 1 pieces per EUR 11,32
From 20 pieces per EUR 9,16
From 40 pieces per EUR 8,09
From 100 pieces per EUR 7,28
in stock: 0 pieces
Single price: EUR 7,28 - EUR 11,32 per pieces
Total price:

EUR 7,28 - EUR 11,32

Quantity exceeded the max. order quantity (max. 50.000)

General parameters

Series series 713
Area (short) M12-A
Connector design Female angled connector
Termination wire clamp
Connector locking system screw
Mounting type Cable mounting
Bereich Automation Technology - Sensors and Actuators

Electrical parameters

Rated voltage (V) 250 V
Rated current (40 °C) 4.0 A
Insulation resistance > 108 Ω
Contact resistance ≤ 3 mΩ
Insulating material group III
Overvoltage category II
Pollution degree 3
EMC compliance unshielded

Material characteristics

Housing material PA
Contact material CuSn (bronze)
Contact body material PA
Locking material Zinc die-cast nickel-plated
RoHS value Keine
RoHS description Keine Schadstoffe
SCIP number 44bbe5b6-046f-42ff-bd22-877cafa8ee66
SVHC description Imidazolidine-2-thione
SVHC value CAS 96-45-7

Technical characteristics

Cable outlet 6.0-8.0 mm
Cross-sectional area (AWG) AWG 20
Cross-sectional area (mm) max. 0.50 mm²
Degree of protection IP67

Other

Security notice 1 The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
Security notice 2 The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
Security notice 3 To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to conn
Security notice 4 Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
Security notice 6 Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the
Security notice 8 To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
customs tariff number 85369010
Aliases 9905245204
99.0524.52.04