binder SERIE 694 KABELSTECKER FÜR 10-12MM

product number: 99 0717 00 13

  • Manufacturer: binder
Picture may vary

Description:
RD30 Male cable connector, Contacts: 12+PE, 10.0-12.0 mm, unshielded, solder, IP65
From 1 pieces per EUR 17,03
From 20 pieces per EUR 13,63
From 40 pieces per EUR 12,11
From 100 pieces per EUR 10,98
Delivery time: from stock
in stock: 35 pieces
Single price: EUR 10,98 - EUR 17,03 per pieces
Total price:

EUR 10,98 - EUR 17,03

Quantity exceeded the max. order quantity (max. 50.000)

General parameters

Series series 694
Area (short) RD30
Connector design Male cable connector
Termination solder
Connector locking system screw
Mounting type Cable mounting
Bereich Power Connectors

Electrical parameters

Rated voltage (V) 250 V
Rated current (40 °C) 6.0 A
Insulation resistance ≥ 1010 Ω
Contact resistance ≤ 5 mΩ
Insulating material group III
Overvoltage category III
Pollution degree 3
EMC compliance unshielded

Material characteristics

Housing material PA
Contact material CuZn (brass)
Contact body material PA (UL94 HB)
RoHS value (Pb)
RoHS description Blei
SCIP number 9296811f-953b-4e43-ab43-081cd0a079a6
SVHC description Lead
SVHC value CAS 7439-92-1

Technical characteristics

Cable outlet 10.0-12.0 mm
Cross-sectional area (AWG) AWG 17
Cross-sectional area (mm) max. 1.00 mm²
Degree of protection IP65

Other

Security notice 1 The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
Security notice 2 The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
Security notice 3 To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to conn
Security notice 4 Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
Security notice 6 Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the
Security notice 8 To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 50 cNm).
customs tariff number 85369010
Aliases 9907170013
99.0717.00.13
99-0717-00-13

EVG. So Ideas turn into solutions.

Contact us