binder KABELSTECKER

product number: 99 9105 02 03

  • Manufacturer: binder
Picture may vary

Description:
Snap-In Male cable connector, Contacts: 3, 6.0-8.0 mm, unshielded, solder, IP67, UL, VDE
From 1 pieces per EUR 4,49
From 20 pieces per EUR 3,64
From 40 pieces per EUR 3,21
From 100 pieces per EUR 2,95
Delivery time: from stock
in stock: 98 pieces
Single price: EUR 2,95 - EUR 4,49 per pieces
Total price:

EUR 2,95 - EUR 4,49

Quantity exceeded the max. order quantity (max. 50.000)

General parameters

Series series 720
Area (short) Snap-In IP67
Connector design Male cable connector
Termination solder
Connector locking system snap-in
Mounting type Cable mounting
Bereich Miniature Connectors

Electrical parameters

Rated voltage (V) 250 V
Rated current (40 °C) 7.0 A
Insulation resistance ≥ 1010 Ω
Contact resistance ≤ 3 mΩ
Insulating material group II
Overvoltage category II
Pollution degree 2
EMC compliance unshielded

Material characteristics

Housing material PA
Contact material CuZn (brass)
Contact body material PA (UL94 V-0)
RoHS value (Pb)
RoHS description Blei
SCIP number c498f315-df09-47e6-b514-3a9e45c42b96
SVHC description Imidazolidine-2-thione, Lead
SVHC value CAS 96-45-7, CAS 7439-92-1

Technical characteristics

Cable outlet 6.0-8.0 mm
Cross-sectional area (AWG) AWG 18
Cross-sectional area (mm) max. 0.75 mm²
Degree of protection IP67

Other

Approval 1 UL
Approval 2 VDE
Security notice 1 The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
Security notice 2 The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
Security notice 3 To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to conn
Security notice 4 Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
Security notice 6 Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the
customs tariff number 85369010